标题:Complexity Analysis of Physiological Time Series Using a Novel Permutation-Ratio Entropy
作者:Zhang, Yatao; Liu, Chengyu; Wei, Shoushui; Liu, Yungang; Liu, Hai
作者机构:[Zhang, Yatao; Wei, Shoushui; Liu, Yungang] Shandong Univ, Sch Control Sci & Engn, Jinan 17923, Shandong, Peoples R China.; [Zhang, Yatao; Liu, Hai] 更多
通讯作者:Zhang, YT;Zhang, YT;Zhang, Yatao
通讯作者地址:[Zhang, YT]Shandong Univ, Sch Control Sci & Engn, Jinan 17923, Shandong, Peoples R China;[Zhang, YT]Shandong Univ, Sch Mech Elect & Informat Engn, Wei 更多
来源:IEEE ACCESS
出版年:2018
卷:6
页码:67653-67664
DOI:10.1109/ACCESS.2018.2879725
关键词:Permutation-ratio entropy (pre); complexity; chaotic properties;; physiological time series
摘要:To date, various information entropy methods have been employed to evaluate complexity within physiological time series. However, such methods cannot discern different levels of nonlinear chaotic properties within time series, indicating that incorrect results are yielded due to noise. Herein, a novel permutation-ratio entropy (PRE) method was proposed and compared with the classical permutation entropy (PE) method, multiscale PE with scale factors 4 and 8 (MPE_S4 and MPE_S8). Simulations with clean logistic mapping series and the logistic mapping series plus noise with a signal-to-noise ratio of 20 dB showed that only PRE monotonically declined with complexity reduction within time series for all 12 combinations of parameters (time delay tau and embedded dimension m). By contrast, PE only monotonically decreased at three parameter combinations for the clean logistic series and failed at all 12 parameter combinations for the logistic series plus noise, and moreover, MPE_S4 and MPE_S8 failed to monotonically decline for the clean logistic series and the logistic series plus noise at all parameter combinations. Results of surrogate data analysis indicated that PRE could more effectively measure the deterministic components of nonlinear within time series than PE, MPE_S4 and MPE_S8. In addition, the parameter m could enable PE, MPE_S4, and MPE_S8 to yield incorrect results, but it could not do so for PRE. Both PRE and PE were relatively stable on various parameters of tau. Interictal and ictal electroencephalography (EEG) recordings from the Bonn database and the CHB-MIT scalp EEG database were also observed, and the results indicated that the PRE could accurately measure the complexity of EEG recordings, as shown by higher entropy values yielded from interictal intracranial EEG recordings versus those yielded from ictal ones (p < 0.01).
收录类别:EI;SCOPUS;SCIE
资源类型:期刊论文
原文链接:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85056562102&doi=10.1109%2fACCESS.2018.2879725&partnerID=40&md5=7fd887f5470bf76aadcef028bbd88a83
TOP