标题:Low concentration acetone gas sensing properties of 3 wt% Pd-doped SmCoxFe1-xO3nanocrystalline powders under UV light illumination
作者:Zhang, Heng ;Qin, Hongwei ;Zhang, Panpan ;Chen, Yanping ;Hu, Jifan
作者机构:[Zhang, Heng ;Qin, Hongwei ;Chen, Yanping ;Hu, Jifan ] School of Physics, State Key Laboratory for Crystal Materials, Shandong University, Jinan; 2501 更多
通讯作者:Qin, Hongwei
来源:Sensors and Actuators, B: Chemical
出版年:2018
卷:260
页码:33-41
DOI:10.1016/j.snb.2017.12.114
摘要:3 wt% Pd-doped SmCoxFe1-xO3nanocrystalline powders were prepared by the sol-gel method and annealed at 750 °C. The sensing response of Pd:SmCo0.1Fe0.9O3was measured to be 1.62, 1.85, 2.21, 2.59, 3.69, 8.48, and 13.86 for 0.01, 0.02, 0.05, 0.1, 0.2, 0.5 and 1 ppm acetone gas, respectively, at an optimal operating temperature of 220 °C. The response and recovery times following exposure to 0.5 ppm acetone gas were 32 s and 13 s, respectively. To decrease the optimal operating temperature, UV light illumination at a wavelength of 365 nm was introduced. Under the UV light, the response showed a large improvement to 1.98, 2.53, 3.68, 5.03, 7.68, 10.31, and 15.85 for the same acetone gas concentrations, respectively, at an optimal operating temperature of 160 °C. Pd:SmCoxFe1-xO3can be used to distinguish between healthy individuals and possible diabetic patients. Exhaled breath from four volunteers was detected under UV-light illumination. The resulting data show that the exhaled breath from diabetics contained more than 1 ppm acetone gas, while approximately 0.2 ppm acetone gas was detected in the exhaled breath from healthy individuals.
© 2017
收录类别:EI
资源类型:期刊论文