标题:PandaX: a liquid xenon dark matter experiment at CJPL
作者:Cao XiGuang; Chen Xun; Chen YunHua; Cui XiangYi; Fang DeQing; Fu ChangBo; Giboni, Karl L.; Gong HaoWei; Guo GuoDong; He Ming; Hu J 更多
作者机构:[Chen Xun; Cui XiangYi; Fu ChangBo; Giboni, Karl L.; Gong HaoWei; Guo GuoDong; He Ming; Hu Jie; Ji XiangDong; Li ShaoLi; Lin Qing; Liu JiangLai; Liu X 更多
通讯作者:Ji, X
通讯作者地址:[Ji, XD]Shanghai Jiao Tong Univ, Inst Nucl & Particle Phys Astron & Cosmol INPAC, Shanghai 200240, Peoples R China.
来源:SCIENCE CHINA-PHYSICS MECHANICS & ASTRONOMY
出版年:2014
卷:57
期:8
页码:1476-1494
DOI:10.1007/s11433-014-5521-2
关键词:dark matter; liquid xenon detector; underground experiment; time; projection chamber
摘要:PandaX is a large liquid-xenon detector experiment usable for direct dark-matter detection and Xe-136 double-beta decay search. The central vessel was designed to accommodate a staged target volume increase from initially 120 kg (stage I) to 0.5 t (stage II) and eventually to a multi-ton scale. The experiment is located in the Jinping Deep-Underground Laboratory in Sichuan, China. The detector operates in dual-phase mode, allowing detection of both prompt scintillation, and ionization charge through proportional scintillation. In this paper a detailed description of the stage I detector design and performance as well as results established during the commissioning phase are presented.
收录类别:EI;SCOPUS;SCIE
WOS核心被引频次:56
Scopus被引频次:53
资源类型:期刊论文
原文链接:https://www.scopus.com/inward/record.uri?eid=2-s2.0-84904401801&doi=10.1007%2fs11433-014-5521-2&partnerID=40&md5=5e8ce9c4b4bdb582b919068ce230dc9f