摘要:A model between measuring error of component power flow in pipes and mounting deviation is developed. The proposed model shows that the component power flow is more prone to influenced by position deviation, and 5% deviation might result in 10% measuring error. Moreover, contrary to the total power flow, the error of the component power flow is also related to choice of grid origin and amplitude ratio of two component waves. © (2013) Trans Tech Publications, Switzerland.