标题:Attenuation auto-correction method in Raman distributed temperature measurement system
作者:Wang, Z. L.; Zhang, S. S.; Chang, J.; Lv, G. P.; Wang, W. J.; Jiang, S.; Liu, X. Z.; Liu, X. H.; Luo, S.; Sun, B. N.; Liu, Y. N.
作者机构:[Wang, Z. L.; Zhang, S. S.; Chang, J.; Lv, G. P.; Wang, W. J.; Jiang, S.; Liu, X. H.; Luo, S.; Sun, B. N.; Liu, Y. N.] Shandong Univ, Shandong Prov Ke 更多
通讯作者:Chang, J
通讯作者地址:[Chang, J]Shandong Univ, Shandong Prov Key Lab Laser Technol & Applicat, Sch Informat Sci & Engn, Jinan 250100, Peoples R China.
来源:OPTICAL AND QUANTUM ELECTRONICS
出版年:2013
卷:45
期:10
页码:1087-1094
DOI:10.1007/s11082-013-9720-2
关键词:Attenuation auto-correction; Loop configuration; Distributed temperature; sensing
摘要:A novel method to auto-correct and compensate the attenuation in Raman distributed temperature sensors is proposed. This method utilizes a fiber in loop configuration combined with a reference temperature in the front section to cancel out the impact of attenuation generated by different wavelengths, local external perturbations and environment changes. The conception is successfully verified by theory and experiments. Rapid measurements are shown, with 1,250 m fiber in loop configuration, allowing for a improved temperature accuracy compared to the conventional method.
收录类别:EI;SCOPUS;SCIE
WOS核心被引频次:8
Scopus被引频次:11
资源类型:期刊论文
原文链接:https://www.scopus.com/inward/record.uri?eid=2-s2.0-84884588767&doi=10.1007%2fs11082-013-9720-2&partnerID=40&md5=5a95933d6e044a1ecbe49ca34c322986