标题:LC-MS for Simultaneous Determination of Vancomycin and Teicoplanin in Patient Plasma and its Application to Therapeutic Drug Monitoring
作者:Yuan, Guiyan; Liu, Danni; Bu, Fanlong; Wang, Yanyan; Wang, Benjie; Guo, Ruichen
作者机构:[Yuan, Guiyan; Bu, Fanlong; Wang, Yanyan; Wang, Benjie; Guo, Ruichen] Shandong Univ, Inst Clin Pharmacol, Qilu Hosp, 107 Wenhua Xi Rd, Jinan 250012, S 更多
通讯作者:Guo, RC
通讯作者地址:[Guo, RC]Shandong Univ, Inst Clin Pharmacol, Qilu Hosp, 107 Wenhua Xi Rd, Jinan 250012, Shandong, Peoples R China.
来源:CURRENT PHARMACEUTICAL ANALYSIS
出版年:2019
卷:15
期:1
页码:95-102
DOI:10.2174/1573412914666180801095208
关键词:Vancomycin; teicoplanin; therapeutic drug monitoring; LC-MS;; determination; plasma
摘要:Background: Therapeutic drug monitoring is recommended for patients taking vancomycin and teicoplanin to ensure pharmaceutical efficacy and prevent toxicity. Only few studies were reported regarding the simultaneous determination of vancomycin and teicoplanin in human plasma.; Objective: The study aimed at developing and validating a Liquid Chromatography-Mass Spectrometry (LC-MS) method for simultaneous determination and therapeutic drug monitoring of vancomycin and teicoplanin in patients with severe infection.; Method: Plasma was processed by protein precipitation extraction. The analytes were separated on a C-18 column by gradient elution with 0.1% formic acid and acetonitrile as mobile phase and measured by electrospray ionization source in positive selective ion monitoring mode at m/z 724.7 (vancomycin), 940.7 (teicoplanin) and 329.0 (bergenin). The plasma samples (104) were obtained from patients who were taking vancomycin or teicoplanin for further analysis.; Results: The calibration curves were linear within the range of 0.25-40 mu g/mL for vancomycin, and 0.5-40 mu g/mL for teicoplanin. Either inter- or intra-day precision was less than 10.01 %. The extraction recoveries ranged from 89.99 to 94.29% for vancomycin and from 39.83 to 40.16 % for teicoplanin. Vancomycin and teicoplanin in plasma were stable at various storage conditions. The measured mean trough concentrations were 12.313 mu g/mL for vancomycin and 8.765 mu g/mL for teicoplanin.; Conclusion: This method was successfully applied to therapeutic drug monitoring of vancomycin and teicoplanin in patients. It is with great clinic value for monitoring and predicting the individual response of patients under treatment.
收录类别:SCOPUS;SCIE
资源类型:期刊论文
原文链接:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85059273436&doi=10.2174%2f1573412914666180801095208&partnerID=40&md5=9515bff3c31856f0bdeff62ad2834b60
TOP