标题:Influence of installation deviation on dynamic performance of synchronous magnetic coupling
作者:Zhang, Jian ;Liu, Yanjun ;Liu, Jingwen ;He, Tongtong ;Xie, Yudong
通讯作者:Liu, Yanjun
作者机构:[Zhang, Jian ;Liu, Jingwen ] School of Mechanical Engineering, Shandong University, Jinan, China;[Xie, Yudong ] Institute of Marine Science and Techno 更多
会议名称:26th International Conference on Vibroengineering
会议日期:29 June 2017 through 30 June 2017
来源:Vibroengineering Procedia
出版年:2017
卷:12
页码:78-83
DOI:10.21595/vp.2017.18600
关键词:Dynamic performance; Installation deviation.; Synchronous magnetic coupling
摘要:To improve dynamic characteristics of synchronous magnetic coupling, this paper mainly analyzed the influence of the installation deviation on the synchronous magnetic couplings dynamic performance used in the horizontal axis wave energy power generation device. Dynamic characteristics equations based on Lagrange equation are built in the paper to analyze the dynamic characteristic of synchronous magnetic coupling. The radial deviation, the angle deviation and the center-of-mass deviation are considered in the equation. The influence of those installation deviations on the synchronous magnetic coupling performance is analyzed based on the mathematical model. The results show that the rise time, the overshoot, the peak time, the adjusting time and the oscillation of the synchronous magnetic coupling are almost not affected by those installation deviations. © JVE INTERNATIONAL LTD.
收录类别:EI;SCOPUS
资源类型:会议论文;期刊论文
原文链接:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85027271637&doi=10.21595%2fvp.2017.18600&partnerID=40&md5=2e979adf07641438687d3349778a19ef